Active since 2026
Single-family new construction (demo of existing structure)
👷 Lead:
Stewart Construction
🪪 CL-24-0093
▶ BDR2024-0069 ↗ Construction Single-family new construction (demo of existing structure) Active $4.5M 5/18/2026
$4.5M ground-up replacement in Wilson — Jeff Neishabouri tears down existing 1,800 SF home to build 7,850 SF Type VB residence with natural wood siding and four gas furnaces; out-of-state architect Brian Junge / Heart Healthy Design (Utah, 801-828-0557) leading design with 6 documents filed.
📎 6 docs
📜 13 cond.· 8 awaiting
▶ 📎 Documents (6)
▶ 📜 Conditions (13) 8 awaiting
- Awaiting Verification Structures greater than 5,000 gross square feet are required to be fire sprinklered.
- — Stamped and approved job site plans shall remain on site throughout the project.
- Awaiting Verification A Certificate of Placement prepared by a Wyoming licensed Professional Land Surveyor is required for each structure. The location of the structure foundation shall be prepared by the Professional Land Surveyor and submitted to the Teton County Planning & Building Services Department prior to the foundation walls being poured. A foundation wall inspection cannot be scheduled until receipt of certificate showing the location of the foundation matches the approved plans and is approved by the Planning Department.
- Awaiting Verification All exterior lighting shall comply with the Exterior Lighting Standards of Section 5.3.1, Land Development Regulations. Lighting shall be installed per the approved plans. Should the exterior lighting change in any way, the applicant shall submit revisions including spec sheets to the Planning Department for review and approval, prior to issuance of a Certificate of Occupancy or prior to final inspection of the permitted work. Changes to lighting that require review include fixture design, location of fixtures, the number of fixtures, and lumen amount. This permit approved for 12 shielded light poles (10 ft tall), 12 shielded pathway bollard lights and 12 shielded carriage lights.
- Awaiting Verification Approved bear resistant trash containers are required per Section 5.1.3, Wild Animal Feeding, Land Development Regulations. At construction sites, all trash receptacles for trash that includes food, food wrappers, or other bear attractants shall be bear-resistant. Containers shall be kept closed and latched at all times. Non-bear-resistant dumpsters or trailers may only be used to store construction trash that does not contain bear-attractants.
- Awaiting Verification All fencing on site shall comply with Sec. 5.1.2. Wildlife Friendly Fencing, of the Land Development Regulations, which restricts fence height to 38 inches above ground unless containing livestock, which allows 42 inches. The bottom rail shall be no less than 18 inches above the ground. Spacing between the top rail/wire and adjacent rail/wire shall be at least 12 inches. Buck & rail fencing is prohibited. The pickleball fencing is approved to be special purpose non-wildlife exclusionary fencing.
- — Any changes to the design, including the structure or site development, require a plan revision. Please submit to the Building Division a Letter of Transmittal for Building Permit Revision with appropriate revised drawings. Fees will be assessed for additional square footages, plumbing, mechanical or electrical work, including additional plan review fees. Revisions to Grading and Septic may also be applicable.
- Awaiting Verification Prior to start of construction, wetland setbacks shall be well delineated by temporary silt or construction fencing. Construction-related activity is prohibited within the wetland or associated 30-foot setback. Setbacks shall be well-marked prior to construction and maintained through the project. No parking, storage of materials or any disturbances are permitted in the wetland or setback.
- Awaiting Verification Prior to Certificate of Occupancy staff shall inspect the habitat pond and buffer reclamation. A financial assurance may be required at that time if the revegetation has not been completed sufficiently.
- — Approval of this building permit does not constitute approval of any uses other than those already contemplated by the Bar J Chuckwagon Special Project. The use of the residence is for single-family occupancy, no short term rentals permitted.
- — Approval of this permit does not constitute approval of BDR2024-0152, BDR2024-0153, BDR2024-0154 or BDR2024-0155.
- Awaiting Verification All existing non-compliant signage on the front gate must be removed immediately and will be inspected prior to Certificate of Occupancy for BDR2024-0069 or upon installation of the new entry gate MIS2024-0066, whichever occurs first.
- — All conditions of BUP2024-0018 shall apply to the pond construction.